Monographs: Pharmaceutical substances: Misoprostol dispersion (Misoprostoli dispersio)2016-01
Description. A white or almost white powder. Category. Prostaglandin (PGE1) analogue. Storage. Misoprostol is hygroscopic, misoprostol dispersion it should be stored below 8 °C under nitrogen in sealed containers, protected from light, and should not be exposed to moisture. Requirements Definition. Misoprostol dispersion is a mixture of Misoprostol and Hypromellose. It contains not less than 95.0% and not more than 105.0% of the amount of C22H38O5 stated on the label. Identity tests
Loss on drying. Dry about 300 mg of the dispersion at 105 °C for 2 hours; it loses not more than 15 mg/g. Related substances Prepare fresh solutions and perform the tests without delay. Carry out the test as described under 1.14.4 High performance liquid chromatography using a stainless steel column (15 cm × 4.6 mm) packed with octadecylsilyl silica gel (5 μm). Use the following conditions for gradient elution:
tr = retention time of misoprostol determined with solution (1) Maintain the column temperature at 35 °C. Prepare the following solutions using a mixture of 31 volumes of acetonitrile R and 69 volumes of water as solvent. For solution (1) mix a quantity of the dispersion equivalent to about 8 mg of misoprostol, accurately weighed, with 20.0 mL of acetonitrile R and sonicate for 10 minutes. Ensure that the temperature of the sonication bath is below room temperature to avoid degradation of misoprostol. Centrifuge and filter the supernatant. Evaporate 8.0 mL of the filtrate to dryness under a stream of nitrogen, dissolve the residue in 4.0 mL of solvent, using a vortex mixer. For solution (2) dilute 1 volume of solution (1) to 500 volumes. For solution (3) heat 2 mL of solution (1) in a water bath at 75 °C for 1 hour. Operate with a flow rate of 1.5 mL per minute. As a detector use an ultraviolet spectrophotometer set at a wavelength of about 200 nm. Inject 100 µL of solution (3). The test is not valid unless the peak-to-valley ratio (Hp/Hv) is at least 5.0, where Hp is the height above the extrapolated baseline of the peak due to impurity A (with a relative retention of about 0.95 with reference to misoprostol (retention time about 21 minutes)) and Hv is the height above the extrapolated baseline at the lowest point of the curve separating the peak due to impurity A from the peak due to misoprostol. Inject alternately 100 μL each of solutions (1) and (2). The chromatogram obtained with solution (1) may show the following impurities at the following relative retentions with reference to misoprostol (retention time about 21 minutes): impurity E (1st peak): about 0.84; impurity E (2nd peak): about 0.86; impurity B (1st peak): about 0.90; impurity B (2nd peak): about 0.92; impurity A: about 0.95; impurity D: about 1.27; impurity C: about 1.37. Use also the chromatogram obtained with solution (3) to identify impurity A and C. In the chromatogram obtained with solution (1):
Diastereoisomers Carry out the test as described under 1.14.4 High performance liquid chromatography using a stainless steel column (15 cm × 2.1 mm) packed with hybrid organic silica gel for chromatography R (3.5 μm). As the mobile phase use a mixture of 4 volumes of 2-propanol R, 96 volumes of heptane R and 0.1 volume of trifluoroacetic acid R. Prepare the following test solution using as a solvent a mixture of 4 volumes of 2-propanol R and 96 volumes of heptane R. Mix a quantity of the disperison equivalent to about 2 mg of misoprostol with 5.0 mL of acetonitrile R and sonicate for 10 minutes ensuring that the temperature of the sonication bath is below room temperature to avoid degradation of misoprostol. Centrifuge and filter the supernatant. Evaporate 2.0 mL of the filtrate to dryness with nitrogen, dissolve the residue in 1.0 mL of solvent and vortex for 1 minute. Maintain the column temperature at 25 °C. Operate with a flow rate of 0.5 mL per minute. As a detector use an ultraviolet spectrophotometer set at a wavelength of about 205 nm. Store the samples at 4 °C during analysis, using a cooled autosampler. Inject 10 µL of the test solution. The chromatogram shows two principal peaks due to misoprostol at retention times of about 14 and 16 minutes. The test is not valid unless the resolution between these two peaks is at least 2.0. Measure the areas of the two peaks corresponding to misoprostol. The first peak of misoprostol is 45% to 55% of the sum of the areas of the two peaks due to misoprostol. Assay Carry out the test as described under 1.14.4 High performance liquid chromatography using a stainless steel column (15 cm × 4.6 mm) packed with octadecylsilyl silica gel (5 μm). As the mobile phase use a mixture of 45 volumes of acetonitrile R and 55 volumes of water. Prepare the following solutions in the mobile phase. For solution (1) mix a quantity of the dispersion equivalent to about 4 mg of misoprostol, accurately weighed, with 200.0 mL of mobile phase and sonicate for 10 minutes. Ensure that the temperature of the sonication bath is below room temperature to avoid degradation of misoprostol. Filter a portion of this solution, discarding the first few mL of the filtrate. For solution (B) use 20 μg of misoprostol RS per mL. Maintain the column temperature at 35 °C. Operate with a flow rate of 1.5 mL per minute. As a detector use an ultraviolet spectrophotometer set at a wavelength of about 200 nm. Store the samples at 4 °C during analysis, using a cooled autosampler. Inject alternately 100 μL each of solutions (1) and (2). The test is not valid unless the symmetry factor of the peak due to misoprostol is between 0.8 and 1.5. Measure the areas of the peak responses obtained in the chromatograms from solutions (1) and (2) and calculate the percentage content of misoprostol (C22H38O5) in the dispersion, using the declared content of C22H38O5 in misoprostol RS. Impurities The impurities limited by the requirements of this monograph are those listed in the monograph for Misoprostol.
|