Monographs: Radiopharmaceuticals: Specific monographs: Technetium (99mTc) colloidal tin injection (Stanni colloidalis et technetii (99mTc) injectio)Description. Technetium (99mTc) colloidal tin injection is a clear, colourless, colloidal dispersion. Technetium-99m has a half-life of 6.02 hours. Category. Diagnostic. Storage. Technetium (99mTc) colloidal tin injection should be kept at a temperature between 2°C to 8°C. Additional information. Wherever V is used within the tests of this monograph, V is the maximum recommended dose in millilitres. Syringes for handling the eluate intended for labelling of the final product, or the final product, should not contain rubber parts. Requirements Complies with the monograph for “Parenteral Preparations” and with that for “Radiopharmaceuticals”. Definition. Technetium (99mTc) colloidal tin injection is a sterile, colloidal dispersion of tin labelled with technetium-99m. The injection is suitable for intravenous administration and contains sufficient sodium chloride to make the solution isotonic with blood. The content of technetium-99m is not less than 90% and not more than 110% of the content of technetium-99m stated on the label at the reference date and time stated on the label. Not less than 95% of the total technetium-99m radioactivity is present in colloidal form. The injection contains a variable quantity of tin (Sn) not more than 1 mg/mL. Manufacture Radionuclide production. Technetium-99m is a radioactive nuclide formed by the radioactive decay of molybdenum-99. Molybdenum-99 is a radioactive isotope of molybdenum and may be produced by neutron irradiation of natural molybdenum or of molybdenum enriched in molybdenum-98 or it may be produced by uranium fission. Production of radiopharmaceutical preparation. Technetium (99mTc) colloidal tin injection is prepared aseptically from sterile starting materials such as a sterile kit containing stannous fluoride or stannous chloride and sodium pertechnetate (99mTc) injection (fission or non-fission). The injection may contain a suitable stabilizing, colloid-protecting substance and a suitable buffer. Technetium (99mTc) colloidal tin injection may also be prepared under aseptic processing combined with sterilization by Filtration (see 5.8 Methods of sterilization). Identity tests • Either tests A and B or tests A and C may be applied.
pH value. Carry out the test as described in the monograph for “Radiopharmaceuticals”. pH of the injection, 4.0 to 7.0. Sterility. The injection complies with 3.2 Test for sterility, modified as described in the monograph for “Radiopharmaceuticals”. Test for sterility will be initiated on the day of manufacture. The injection may be released for use before completion of the test. Bacterial endotoxins. Carry out the test as described under 3.4 Test for bacterial endotoxins, modified as described in the monograph for “Radiopharmaceuticals”. The injection contains not more than 175/V I.U. of endotoxins per millilitre. The injection may be released for use before completion of the test. Radionuclidic purity. Record the gamma-ray spectrum using a suitable instrument and measure the half-life using a suitable method. Determine the relative amounts of technetium-99m and radionuclidic impurities that may be present. Radiochemical purity. Carry out the test as described under 1.14.2 Paper chromatography and ascending conditions, using cellulose paper strips. Apply to the paper about 5 μl of the injection to be examined, suitably diluted to give an optimum count rate and develop for a distance of 10 cm with sodium chloride (9 g/l) TS. Allow the paper to dry in air and determine the radioactivity distribution by a suitable method. In this system, technetium- 99m colloidal tin has an Rf value of about 0 and the technetium-99m pertechnetate ion has an Rf value of about 0.6. Not less than 95% of the total radioactivity is in the spot corresponding to technetium- 99m colloidal tin. Chemical purity
Radioactivity. Measure the radioactivity as described under R.1.1 Detection and measurement of radioactivity in a suitable calibrated counting equipment by comparison with a standardized technetium-99m solution or by measurement in an instrument calibrated with the aid of such a solution (a good approximation may be obtained using an ionization chamber and employing a standardized solution of cobalt-57 provided that correction for the differences in the radiations emitted are made). Standardized technetium-99m and cobalt-57 solutions are available from laboratories recognized by the relevant national or regional authority. Biodistribution. Carry out the test as described under R3.1 Biological distribution using a set of three mice as described. At 30 minutes post injection, the sum of the percentages of radioactivity found in the liver and the spleen should not be less than 80 % of the injected radioactivity. Less than 5% of the injected activity should be found in lungs. |